fssafdcFWDg1ge a publié une note il y a 1 an et 6 mois
Customized Micro Data Center Description The modular data center adopts highly integrated design, integrating subsystems such as power supply and distribution, refrigeration, rack, wiring, monitoring system and so on. All subsystems are prefabricated in the factory and only need to be assembled on site. The system is equipped with an independent cold channel, and a separate air conditioning cabinet can be flexibly deployed at any position in the channel to effectively solve local hot spots. The 3D visual management system realizes the intelligent linkage control of power supply and distribution and refrigeration, and automatically manages the computer room assets, significantly improving the reliability, energy saving and operation and maintenance efficiency of the data center. Features N + 1/2N design of key equipment to ensure stable operation to the greatest extent; Multipoint temperature monitoring to prevent loose connection, heating and fire; Near end refrigeration can effectively eliminate local hot spots and support high-density deployment; Sealed channel design to isolate cold and hot air flow; The maximum support is double row, with a total of 46 cabinet positions; Standardized components, modular architecture, rapid on-demand deployment. Application Enterprise headquarters or large branches, bank head offices and secondary branches, small and medium-sized data centers in many industries such as government, operators, education, medical treatment, finance, energy and telecommunications; Multiple groups of HM-MY can also form a large data center. ConfigurationDescription CabinetTempered glass front door, metal sealed rear door, 19 inch installation size, fully enclosed system, cold and hot channel isolation, strong and weak current separation, etc., number of single row cabinets: 4~24; Number of double row cabinets 4~48 Power supply systemThick tempered glass automatic sliding door, turning skylight to open quickly in case of fire signal UPS systemComply with IEC60320 standard, other standards can be customized, such as smart meter, UPS maintenance bypass interlock, class C lightning arrester, etc Air conditioner systemSingle in single out, online double conversion, equipped with lead-acid battery / lithium battery Emergency fanDirect expansion air cooling, front air supply, rear air return, variable frequency compressor, EC centrifugal fan, cold and hot channel, condensate drainage and active drainage functions Monitoring moduleIt is installed in the cold channel and hot channel of the cabinet, with front air supply and rear air exhaust. The start and stop are controlled by the moving ring monitoring system Fire protection module (optional)Support local management and remote web management; Audible and visual, SMS and email alarm; Detect smoke, temperature, access control, water leakage, lighting, etc CabinetAudible and visual alarm, linkage signal, smoke detector, temperature detector, etc Air conditioner system Power supply system Air conditionerCustomized Micro Data Center website:http://www.huamai.com/idc/micro-data-center/